NETZSCH Pump Solutions in the Food and Pharmaceutical Sectors

We find and develop the perfect positive displacement pump for your individual application

Rainer Gozzer Business Field Manager Foods & Pharmaceuticals

 „In food processing, the production of cosmetics and the pharmaceutical industry in particular, we have to take special care with regard to the consumer. This of course means that all NEMO® and TORNADO® pumps are made according to the nationally and internationally relevant manufacturing and hygiene standards and guidelines.“

Rainer Gozzer
Business Field Manager Foods & Pharmaceuticals


As the world's leading supplier in the field of positive displacement pumps, NETZSCH offers you an individual and innovative solution in the areas of food and pharmaceuticals. With our pumps and systems, you can convey your products gently and cleanly in compliance with all hygiene guidelines.

Due to the wide variety of applications in the food and pharmaceutical sectors, we develop customised and sophisticated pump solutions for your request on a global level. We promise you Proven Excellence - outstanding performance in all areas. Whether in the beverage industry, in the production of foodstuffs, for pumping cosmetics or pharmaceutical products, in dairy operations or for conveying oils and fats, the satisfaction of our customers is always our top priority.

Special challenge: High hygienic standards

„In food processing, the production of cosmetics and the pharmaceutical industry in particular, we have to take special care with regard to the consumer. This of course means that all NEMO® and TORNADO® pumps are made according to the nationally and internationally relevant manufacturing and hygiene standards and guidelines“, says Rainer Gozzer, business field manager food and pharmaceuticals.

To be approved for use in the food and pharmaceutical industries, pumps from NETZSCH are subject to a whole range of hygienic guidelines, from the EHEDG to the 3-A Sanitary Standard to specifications from the US Food and Drug Administration (FDA). Our pumps and systems open up new possibilities for you and your manufacturing processes.

Hygienic pumping of liquids and emptying of barrels

In the food and beverage industry, gentle pumping and compliance with hygiene standards play a crucial role. With the oil-free TORNADO® T.Sano® rotary lobe pump, you can dose even sparkling and semi-sparkling wines extremely precisely and gently at the same time. Since pumping is based on the positive displacement pump principle, pressure fluctuations or shear forces are ruled out. This prevents unwanted foam formation. Thanks to our unique barrel emptying systems, barrels' almost residue-free and hygienic emptying are also no problem. If space is limited, a closed system with a TORNADO® T.Sano® rotary lobe pump is also suitable for emptying. Thanks to the innovative design, you can convey products in a soup kitchen, for example, under the highest hygiene standards.

Efficient and temperature-controlled conveying of critical media

In the food and beverage industry, gentle pumping and compliance with hygiene standards play a crucial role. With the oil-free TORNADO® T.Sano® rotary lobe pump, you can dose even sparkling and semi-sparkling wines extremely precisely and gently at the same time. Since pumping is based on the positive displacement pump principle, pressure fluctuations or shear forces are ruled out. This prevents unwanted foam formation. Thanks to our unique barrel emptying systems, barrels' almost residue-free and hygienic emptying are also no problem. If space is limited, a closed system with a TORNADO® T.Sano® rotary lobe pump is also suitable for emptying. Thanks to the innovative design, you can convey products in a soup kitchen, for example, under the highest hygiene standards.

Hygienic, flexible and gentle transport of edible oils and fats

The pumping of edible oils and fats entails a wide variety of requirements. In addition to the high hygienic conditions, the TORNADO® T.Sano® rotary lobe pump offers you meagre maintenance costs. In addition, the rotary lobe pump ensures gentle and efficient pumping. This makes it suitable even for the production of products such as mayonnaise. Thanks to the innovative design and the unique belt drive, the rotary lobe pump gives you the maximum flexibility in every application situation. If required, the T.Sano® can be mounted on a mobile stand.

Hygienic and reliable conveying in dairies

Particularly demanding media such as yoghurt, milk, condensed milk or other dairy products require extremely gentle conveying in compliance with the strictest hygiene standards. With the NEMO® progressing cavity pump, you can transport even the most demanding products without wear and lubrication. This enables you to convey aseptic products and it protects your product from contamination. Thanks to the dead space-free design, the progressing cavity pump can be cleaned without being removed from the system. This saves you considerable time and costs during servicing.

Increased efficiency and hygiene when pumping pharmaceutical products

The pumping of pharmaceutical media such as cell mass and suspension, for example in insulin production, requires the highest efficiency and hygiene. Due to the special design of the NEMO® progressing cavity pump without dead space and the optimal cleanability, the pump fulfils even the strictest hygiene guidelines. In addition, the progressing cavity pump offers you long maintenance intervals. The residue-free cleanability in the system and the long service intervals increase your productivity.

Success stories from the food and pharmaceutical sectors

NEMO® Hygienic Progressing Cavity Pumps in Food Industry

Hygienic progressing cavity pumps transport food gently and safely

Displacement pumps are often used in food production where viscous or difficult media such as molasses, honey, spent grains from beer brewing or chocolate have to be conveyed. More...

TORNADO® Rotary Lobe Pump T.Sano® Empties Barrels

Rotary lobe pump facilitate barrel emptying for a sauce manufacturer

When it comes to conveying systems in the foodstuff industry, the main focus is primarily on hygiene, cleanability and compatibility with food. When emptying containers using progressing cavity pumps for example, barrels can be drained to a residual quantity of less than one percent. More...

NEMO® Progressing Cavity Pumps with Open Hopper Convey Abrasive Spent Grains

Pennsylvania Brewing Company counts on Bavarian pump technology

In 1996 two friends with a passion for brewing premium beer opened the doors to the Brewing Company, a bar, restaurant and brewery in Downingtown, Pennsylvania. More...

Oil-Free TORNADO® T.Sano® Rotary Lobe Pump Delivers Gently

Pumping Sparkling Wine Without Foaming

Due to their sensitivity, wines are considered to be a difficult fluid to pump, while carbonated wines present completely different challenges. More...

NEMO® Hygienic Progressing Cavity Pumps for CIP or SIP Processes

Increased efficiency and hygiene in insulin production

Globally, there are around 285 million people who suffer from diabetes according to the estimates of the International Diabetes Federation (IDF) and this figure is predicted to be 438 million by 2030. More...

NEMO® Progressing Cavity Pumps Convey Hygienically

NEMO® progressing cavity pump reliably in application at a diary

A dairy in the US-State Wisconsin is specialized in liquid concentrated dairy blends. It is one of the largest manufacturer of frozen dairy mixes in the midwest and nationwide the largest producer of sweetened condensed milk. More...

NEMO® Aseptic Progressing Cavity Pump Conveying Yoghurt

Hygienic pump enables efficient and smooth yoghurt conveyance

Yoghurt is one of the exceptionally demanding conveyor media in the food sector. On the one hand, it is vital to avoid strong shear forces so as to protect the valuable bacteria cultures and prevent separation of the different phases. More...    

TORNADO® T.Sano® Rotary Lobe Pump in FSIP® Design Operates Maintenance-Free

Rotary Lobe Pump fills NETZSCH bead mill reliably

The Association of the German Confectionery Industry (BDSI) estimates that around 3.8 million tons of sweets and snacks were consumed in Germany in 2017. More...

NEMO® Hygienic Progressing Cavity Pump Standards of Hygiene

Special food pump even conveys difficult baking mix

As popular as bakery products are, their production is often not without unforeseen difficulties, as for instance in a company making confectionery products in Southern Germany. More...    

NEMO® Progressing Cavity Pump with Heating Jacket

Chocolate pump enables tempering across whole conveying area

Statistics tell us that every German citizen eats around 9.5 kg of chocolate a year, in the form of bars, hollow figures, pralines and such like. There is a particularly steep rise in consumption at Easter and Christmas. More...

Hygienic TORNADO® T.Sano® Reduces Risk of Contamination

Special oil-free rotary lobe pump reduces oil contamination risk

Mineral oil hydrocarbons (MOH) are created during petroleum refining and are divided into two essential fractions: mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH). More...

TORNADO® T.Sano® Rotary Lobe Pump Meets High Standards of Hygiene

Hygienic rotary lobe pump delivers edible oil flexibly and with care

In everyday practice in the foodstuff industry high demands on hygienic processing are required for the primarily sensitive products, simultaneously, there is the high pressure of competition and efficiency. More...

NEMO® Progressing Cavity Pumps Convey the Product Gently

Progressing cavity pumps are optimal for mayonnaise production

NETZSCH's NEMO® hygienic pumps have proved to be very well suited to the requirements of mayonnaise production. The progressing cavity pumps work at low speeds and shear rates, which mean the product is protected from high forces. More...

NBE Barrel Emptying Unit Self-Priming and Easy to Clean

Barrel emptying system conveys juice with almost no residues

Juices and other drinks generally cause few problems when it comes to a company's internal material logistics - thanks to their good flow characteristics, they are easy to convey and empty out. More...

NEMO® Progressing Cavity Pumps Ensure Gentle and Efficient Conveyance

Progressing cavity pumps gently convey chilli and tomato sauce

A food manufacturer used a multi screw pump to convey hot chilli and tomato sauce until 2015. However, this pump did not achieve the required flow rate and at the same time by shearing reduced the product quality. More...

NETZSCH product portfolio in the food and pharmaceutical sectors

NEMO® Progressing Cavity Pumps

NEMO® progressing cavity pumps have a very broad application range and are used in all branches of industry for the continuous, pressure-stable, gentle and low-pulsation conveyance of almost any substance.

More information

TORNADO® Rotary Lobe Pumps

NETZSCH TORNADO® self-priming, valveless, positive displacement pumps can be optimally customised to meet specific process and application requirements. They are used for continuous and gentle conveying as well as speed-proportional dosing of almost all media.

More information

NOTOS® Multi Screw Pumps

The NOTOS® family has superior quality standards to meet the highest level requirements from our customers. The pumps are designed to work with low to high lubricant fluids, low to high viscosity, shear sensitive and/or chemically agressive media.

More information

Dosing and Emptying

NETZSCH has been developing, producing and marketing NEMO® progressing cavity pumps for over 60 years and is one of the world’s most trend-setting problem solvers in some of the most difficult of applications – particularly in the area of dosing technology.

More information